Storage Tank Testing
and Inspections

Certified Storage Tank Inspection and Testing (NDT)
in the Beckley, WV area

Discover why corporations in the Beckley, WV area choose Genesis Environmental Solutions for aboveground and underground storage tank integrity testing and inspections.

Non-Destructive Testing

Non-Destructive Testing Services

Certified Inspectors

API 1631, 653, 510 and STI SP001 Certified Inspectors

Advanced Testing Techniques

Advanced Testing Techniques

Contact us today to request an estimate

Full Service Storage Tank Testing

Looking for professional storage tank inspections and tank integrity testing in the Beckley, WV area? Genesis Environmental Solutions’ personnel have extensive experience, specialty training and state of the art equipment for inspecting any type of tank including fuel, oil, sludge, water and chemical tanks.

Services and Capabilities

ASME, AWS and API NDE Inspections
Vacuum Box Examination (VB)
Magnetic Flux Leakage (MFL/MFE)
Ultrasonic Thickness Testing (UTT)
Visual Testing (VT)
Shell Plate UT, Head UT, and Through Coating UT
Magnetic Particle Testing (MT)
Penetrant Testing (PT)
Dry Film Coating Inspection
Ultrasonic Shear Wave Testing (UTSW)

Certified to do the job right

Our personnel have certifications from both the American Petroleum Institute and Steel Tank Institute in the inspection and operation of these tanks, including:

  • API 653 Aboveground Storage Tank Inspection Certification
  • API 1631 Underground Storage Tank Inspection Certification
  • API 510 Pressure Vessel Inspection Certification
  • API 570 Piping Inspection Certification
  • Steel Tank Institute (STI) SP001 Tank Inspection Certifications

This combination of expertise and nationally recognized certifications allow us to provide services for all types of projects, from a single fuel station tank to field-built erected tank farms.

You can trust Genesis for professional tank testing and environmental services.

  • The facility manager gave great reports about the Genesis employees on their professionalism and hard work. I have listed below an excerpt: 'Very professional. I would definitely recommend them to anyone else.'

    Jason Crum, Co-op Project Engineer, Ergon, Inc.

Industries Served

Just a sample of the industries we work with in the Beckley, WV area.

Water & Wastewater

Bridge & Highway

Petrochemical

Pipelines & Terminals

Food & Beverage

Manufacturing

Power Generation

municipalities

engineering

Recent Projects

A few examples showing the range of projects that our storage tank division has worked on.

YRC
Inspection & Cleaning Client: YRC Worldwide Inc.

Performed tank cleaning and API 653 tank inspections and similar service inspections for YRC Worldwide. Fuel was removed and recycled prior to cleaning and inspection services.

West Plains Energy
Diesel Storage Tank Client: West Plains Energy

Genesis was awarded this diesel storage tank project from West Plains Energy. The project included a API 653 inspection in addition to a coatings and lining application.

KCPL Tank
5.2 Million Gallon Tank Client: Kansas City Power & Light

Performed tank inspection, cleaning, internal tank lining, piping replacement and containment grading for KCP&L. Project included coatings application on transfer pump station piping.

Contact us today to request an estimate

Our Clients

Clients we've done projects for over the years.

Tank Inspection FAQ

Your questions answered about tank inspections in the Beckley, WV area.

Under 40 CFR 112 (SPCC Rule), facilities in the Beckley area that store 1,320 gallons or more of oil in aboveground tanks (each container ≥ 55 gal) and present a reasonable expectation of discharge into navigable waters—such as the New River and its tributaries flowing through Raleigh County—must prepare and maintain an SPCC Plan. That plan must include documented inspections of tanks, piping, valves, and secondary containment systems to demonstrate ongoing spill prevention readiness.

West Virginia is among the most comprehensive state AST programs in the country. Under W. Va. Code §22-30 and its implementing rule 47 CSR 63, administered by the West Virginia Department of Environmental Protection, Division of Water and Waste, Tanks Unit, all ASTs holding more than 1,320 gallons must be registered with WVDEP and obtain a certificate to operate. Regulated tanks are classified as Level 1 or Level 2 based on proximity to public water supply sources, with higher standards applied to Level 1 tanks. Annual certification is explicitly required by state regulation (47 CSR 63-5.2): qualified-person inspections by a WV-licensed PE, a person under direct PE supervision, or an API- or STI-certified inspector are required on a 3-year cycle for Level 1 ASTs and a 5-year cycle for Level 2 ASTs, with owner/operator self-certification permissible in intervening annual years. Routine visual inspections of secondary containment are required every 14 days for Level 1 tanks and monthly for Level 2 tanks. Owners must also submit Spill Prevention Response Plans, and operating an unregistered AST is unlawful and subject to civil penalties up to $10,000 per tank per day.

Genesis Inspection Services helps Beckley-area businesses operating aboveground storage tanks stay ahead of their compliance obligations throughout Raleigh County and the surrounding region. We perform certified API 653 inspections for field-erected tanks and STI SP001 inspections for shop-built tanks, and we provide the thorough documentation needed to satisfy both EPA SPCC regulations and West Virginia state requirements under W. Va. Code §22-30 and 47 CSR 63.

API 653 inspections are required for large, field-erected aboveground storage tanks (ASTs) that are constructed to the API 650 standard. In Beckley, these tanks are commonly used by petroleum terminals, manufacturing plants, chemical facilities, and utilities to store fuel, oil, or hazardous liquids. If your tank is over 75,000 gallons, made from welded-steel construction, has a diameter of 30 feet or more, or a height of 50 feet or more, there's a high likelihood it falls under API 653 requirements.
STI SP001 inspections are typically required for shop-fabricated aboveground storage tanks under 75,000 gallons, often found at gas stations, commercial facilities, and industrial properties. If you're storing oil or hazardous substances in Beckley, you may be subject to the EPA's Spill Prevention, Control, and Countermeasure (SPCC) rules for this inspection.
The frequency depends on the tank size, contents, and regulatory classification. In general, API 653 recommends formal external inspections every 5 years and internal inspections every 10-20 years. STI SP001 inspection frequency is determined by their size, category, and risk factors. We can help determine your specific schedule.
Yes. All our inspectors hold API 653 and STI SP001 certifications and are trained in accordance with industry and regulatory standards. We are fully qualified to perform inspections anywhere in West Virginia, including Beckley.