Looking for professional storage tank inspections and tank integrity testing in the Fitchburg, MA area? Genesis Environmental Solutions’ personnel have extensive experience, specialty training and state of the art equipment for inspecting any type of tank including fuel, oil, sludge, water and chemical tanks.
Our personnel have certifications from both the American Petroleum Institute and Steel Tank Institute in the inspection and operation of these tanks, including:
This combination of expertise and nationally recognized certifications allow us to provide services for all types of projects, from a single fuel station tank to field-built erected tank farms.
You can trust Genesis for professional tank testing and environmental services.
Genesis Environmental Solutions, Inc. is a Native American Owned Business. MBE and DBE Certified.
Just a sample of the industries we work with in the Fitchburg, MA area.
A few examples showing the range of projects that our storage tank division has worked on.
Performed tank cleaning and API 653 tank inspections and similar service inspections for YRC Worldwide. Fuel was removed and recycled prior to cleaning and inspection services.
Genesis was awarded this diesel storage tank project from West Plains Energy. The project included a API 653 inspection in addition to a coatings and lining application.
Performed tank inspection, cleaning, internal tank lining, piping replacement and containment grading for KCP&L. Project included coatings application on transfer pump station piping.
Clients we've done projects for over the years.
Your questions answered about tank inspections in the Fitchburg, MA area.
Under 40 CFR 112 (SPCC Rule), facilities that store 1,320 gallons or more of oil in ASTs (≥ 55 gal per container) and are likely to discharge into navigable waters must maintain an SPCC Plan. This includes conducting documented inspections of tanks, piping, valves, and secondary containment systems.
502 CMR 5.00 (via the MA State Fire Marshal) requires ASTs over 10,000 gallons (excluding water-only tanks) to obtain state permits and undergo inspections by a qualified, certified inspector as part of the five‑year use-permit renewal process. The regulation mandates inspections in line with an approved standard (e.g., API 653 or STI SP001), certified by a “Qualified Tank Inspector,” such as an API 653 or STI SP001 certified professional. Records must be submitted to the State Fire Marshal within 14 days of inspection.
We support Fitchburg-area facilities operating aboveground storage tanks (ASTs) by performing certified API 653 and STI SP001 inspections—and by providing the detailed reports and documentation required to demonstrate compliance with EPA SPCC rules and Massachusetts AST regulations.